D303
ITEC
D303
Datasheet (PDF) ↗Threaded hygienic diaphragm seal
D303 is a hygienic seal that isolates the measuring instrument from food and pharmaceutical processes. It uses an external threaded process connection and food-grade filling oil in the measuring circuit.
SKU: AN1049
Add to quotation list +Technical specifications
| Compatible measuring range | 1–40 bar. The available range depends on connection standard and size. |
|---|---|
| Standard diaphragm | AISI 316L stainless steel |
| Process connection | External threaded connection. DIN 11851, SMS, RJT/APV or IDF/ISS types |
| Instrument connection | ½-inch female NPT or BSP |
| Standard filling fluid | Food-grade oil (stated filling fluid temperature range: −20…+140 °C) |
| Mounting | Direct as standard |
| Chamber | AISI 316 stainless steel |