AVF7000 Series
ALIA
AVF7000 Series
Datasheet (PDF) ↗Vortex flowmeter
Measures liquid, gas and steam flow using vortices generated in the stream. Temperature and pressure compensation depend on the configuration.
SKU: AN2021
Add to quotation list +Technical specifications
| Measuring range | Steam 1.6~540,000 kg/hr Gas 3~46,000 m3/hr Liquid 0.3~4950 m3/hr |
|---|---|
| Material | Stainless Steel 301 / 304 / 316 |
| Accuracy for liquids | +/-0.7% value of reading Gas & Steam: +/-1.0% value of reading |
| Unit | Nm3/hr, Nm3/min, m3/hr, m3/min, L/hr, L/min, L/s, t/d, t/hr, t/min, kg/hr, kg/m, kg/s, USgal/min, UKgal/min, Scf/hr, cf/hr, lb/hr, bbl/d… |
| Repeatability | +/-0.2% value of reading |
| Process connection | Flange / Wafer Flange Type: JIS 10K / JIS 20K / JIS 40K, ANSI 150# / ANSI 300# / ANSI 600#, DIN PN10 / PN16 / PN25 / PN40 Wafer Type: DN40-DN250 without Temp. / Pressure Sensor |
| Temperature | -40~280 °C (Standard) -40~420 °C (Optional) |
| Ambient temperature | -20~60 °C |
| Pressure | 78 kgf/cm2 (Max.) |
| Ingress protection | IP67 Intrinsically Safe, Eex ia IIC T4 Explosion Proof, Ex d IIC T6 |
| Local indicator | 2 or 3 lines LCD 6 Digit flowrate 8 Digit totalizer |
| Current output | 4-20 mA (2-Wire) with HART signal Load: Rohm= (VDC-12) * 50 |
| Pulse output | Scaled Pulse Load: 1000-5000 Ω |
| Communication | HART (Compatible) or RS485 (MODBUS Protocol) |
| Data retention | Operation parameter and totalizer figures are stored by EEPROM for more than 10 years |
| Body material | Aluminum alloy |
| Cable entry | Standard: M20 * 1.5 Option: 1/2" NPTF |
| Power supply | 12-32 VDC Ni-MH Battery (3 years working hours) |
| Keypad | 3 Internal keys for programming and display control |
| Option | Pressure Sensor: Pressure compensation Signal Output: 0-35 mVDC (20 μA Power Supply) Temperature Sensor: Temperature compensation Signal Output: PT1000 (2-Wire) |