Datasheet (PDF) ↗Clamp-on ultrasonic flowmeter
Measures liquid flow using sensors fitted outside the pipe, without opening the pipe. Pipe material, dimensions and fluid conditions affect sensor selection and measurement performance.
SKU: AN2011
Add to quotation list +Technical specifications
| Measuring principle | Transit time difference |
|---|---|
| Pipe size | NN Type : 25-4000 mm (1"-160") HT Type : 25-4000 mm (1"-160") |
| Pipe material | Cast Iron, Stainless Steel, Ductile Iron, Copper, PVC, Aluminum, Fiberglass etc. |
| Lining material | Tar Epoxy, Rubber, Mortar, Polypropylene, Polystyrol, Polyethylene, Teflon, etc. |
| Sensor body | S.S. 304 |
| Temperature | Sensor NN : -40 ~ 70 °C Sensor HT : -40 ~ 160 °C |
| Display | 2 Lines LCD with illumination Flowrate: 7 Digit with decimal point Totalizer: 8 Digit, Forward, Reverse & Net values. Engineering Unit: m3 , L, USgal, USbbl, ft3 Time Unit: sec, min, hour, day Energy Unit: car/h, Kcal/h, Mcar/h, MJ/h, GJ/h, BTU/h Other: Velocity, Date, Time, Signal condition. |
| Accuracy | +/-1% ~ +/-1.5% of reading (0.5-30 m/s) +/-0.5% of reading (Online calibration) |
| Repeatability | +/-0.2% value of reading |
| 4–20 mA input | 2 points, programable Range |
| Function | Temp. Measurements for Thermal Energy |
| Keypad | 16 Key with tactile action |
| Response time | Less than 1 second |
| Flow velocity | 0.01 ~ +/-32 m/s |
| Resolution | 0.001 m/s |
| Ambient temperature | -20~50 °C |
| Mounting | Wall mounting |
| Maximum cable length | 100 m |
| Power consumption | Less than 3W |
| Power supply | 90-260 VAC 50/60 Hz and 24 VDC +/-10% |
| Data retention | Operation parameter and totalizer figures are stored by EEPROM for more than 10 years |
| Current output | 4-20 mA |
| Pulse output | 1 unit / pulse Rating: 12-24 VDC, 50 mA Max. |
| Communication | RS485 (MODBUS) (Standard) HART (Compatible) (Option) |
| Dimensions | 270 * 185 * 67 mm |
| Weight | 2 kg |
| Ingress protection | Converter: IP65 Sensor: IP68 (Submersible) |