ATT1000 Series
Home › Temperature › ATT1000 Series
ALIA
ATT1000 Series
Datasheet (PDF) ↗Smart temperature transmitter
Converts an RTD, thermocouple, resistance or millivolt input into a process signal. Local configuration and HART communication support temperature measurement integration.
SKU: AN2033
Add to quotation list +Technical specifications
| Inputs | Universal Input Thermalcouple: T/C (K, S, B, E, J, T, R, N)… RTD: CU50 / PT100, 2 / 3 / 4-Wire… mV: -128~128 mV / -1000~1000 mV… Resistance: 0-600 Ω / 0-5000 Ω |
|---|---|
| Accuracy | +/-0.1% of span |
| Stability | +/-0.1% of span for 2 years |
| Temperature effect | +/-0.1% of span per 10 °C |
| Cold junction compensation | +/-0.5 °C |
| Simulation output | 4-20 mA |
| Material | Wetted Parts: S.S. 304 / S.S. 316 / Has. C / Tantalum etc. Housing: Low copper aluminum alloy (Sprayed with light blue polyurethane paint) Module Housing: Flame-resistant PC Name / Tag Plate: Stainless Steel 304 / Stainless Steel 316 |
| Process connection | Threads / Flanges |
| Overtemperature limit | 120% of Full Scale |
| Mounting | Direct mounting or bracket on 2" Pipe |
| Humidity limit | 0-100% Relative Humidity |
| Ambient temperature | -25~85 °C |
| Vibration effect | +/-0.05% of URL per g to 200 Hz in any axis |
| EMI / RFI effect | Follow SAMA PMC 33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m |
| Display | Backlit LCD rotatable to any angle |
| Display function | 5 Digits programmable & 0-100% Bargraph |
| Display unit | °C / °F / °R / °K |
| Adjustment method | B Type: USB + PC software (windows system) C Type: HART signal (Compatible) D Type: HART signal (Compatible)& keypad |
| Current output | 4-20 mA 2-Wire with HART Signal Load: Rohm = (VDC-9) * 50 |
| Power supply | 9-36 VDC |
| Digital communication | HART Protocol |
| Cable entry | M20 Conduit Threads / 1/2" NPT (Female) |
| Damping | 0-32 Seconds |
| Response time | 100 ms |
| Start-up time | 2 Seconds with minimum damping |
| Zero calibration | Automatic zero calibration by press-button |
| Isolation | Input / Output / GND isolated to 480 VDC |
| Power supply effect | +/-0.005 of Span per V |
| Weight | 60 g (Converter only) with display 30 g (Converter only) without display |
| Ingress protection | IP67 (Standard) Intrinsically Safe, Eex ia IIC T5 (Standard) Explosion proof, Ex d IIB T5 |
| Sensor connection | M27 * 2 (Female) |