Datasheet (PDF) ↗FMCW radar level transmitter
Provides non-contact level measurement in liquid and solid applications. Its focused radar beam supports installation in small tanks and challenging vessel geometries.
SKU: AN2024
Add to quotation list +Technical specifications
| Measuring principle | Frequency Modulated Continuous Wave(FMCW) |
|---|---|
| Frequency range | 77-82 GHz |
| Measuring range | 0-150 m |
| Resolution | 1 mm / 0.003 ft |
| Repeatability | +/-0.5 mm |
| Accuracy | +/-2 mm…+/-5 mm |
| Blind zone | 0.01 – 0.03 m |
| Beam angle α | 14° / 8° / 6° / 3° |
| Sensor update rate | >1 s (depending on configuration) |
| Maximum rate of level change | Max. 200 mm/s |
| Ambient temperature effect | +/-1 mm (+/-0.04 in.) / 10 K |
| Process connection | Thread (3/4" NPT, G3/4", 1-1/2" NPT, G1-1/2", G3", 3" NPT) Flange (DN50-DN200) Universal Flange (DN100-DN200) |
| Ingress protection | IP67 Explosion Proof, Ex d IIC T6 Intrinsically Safe, Ex ia IIC T6 |
| Display | 4-6 Digit LCD with Bargraph |
| Keypad | 4 internal keys for programming |
| Unit | ft, in, m, cm, mm |
| Ambient temperature | -40~80 °C |
| Process temperature | -40~260 °C (Max.) |
| Process pressure | -1.0~25 bar G (Max.) |
| Humidity | 0-100% RH, non-condensing |
| Maximum cable length | 40 m (For single cavity housing) |
| Power supply | 15-28 VDC (2-Wire) 24 VDC ± 10% (4-Wire) 90-253 VAC, 50 / 60 Hz (4-Wire) |
| Power consumption | 22.5 mA / 1W (Max.) (2-Wire) |
| Current output | 4-20 mA (2-Wire, 4-Wire) Load: Rohm=(VDC-15) * 50 Resolution: 1.6 μA |
| Damping | 0-999 s |
| Communication | HART signal (Compatible) RS485 (MODBUS Protocol) |
| Data retention | Operation parameters and totalization date are stored by EEPROM for more than 10 years |
| EMI / RFI effect | Follow SAMA PMC 33.1 from 20 to 1000 MHz and for field strengths up to 30 V/m |
| Vibration resistance | 2g at 10-1000 Hz according to IEC 61298-3 |
| Cable entry | Standard: M20, Option: 1/2" NPTF |