AMF900 Series
ALIA
AMF900 Series
Datasheet (PDF) ↗Flanged electromagnetic flowmeter
A flanged sensor for water, wastewater and industrial conductive liquids. Lining, electrodes and converter configuration are selected to suit process conditions.
SKU: AN2010
Add to quotation list +Technical specifications
| Measuring range | Velocity 0-0.25 m/s min 0-12 m/s max |
|---|---|
| Material | Measuring Tube: Stainless Steel 304 Measuring Tube: Stainless Steel 304 Flange: Carbon Steel (Standard), Stainless Steel 304 (Option), Stainless Steel 316, 316L (Option) Coil Housing: Carbon Steel (Standard), Stainless Steel 304 (Option), Stainless Steel 316, 316L (Option) |
| Lining | Polyurethane (25-400 mm), Neoprene (100-2000 mm), FEP (10A-300 mm), PTFE (25-2000 mm), PFA (10A-300 mm) |
| Ingress protection | Junction box IP67, Body IP68, IP68 (Submersible) |
| Conductivity | More than 5 μS/cm |
| Explosion protection | Ex d ia [ia] q llC T6 (with AMC3200, AMC3200DF only) |
| Cable entry | Standard: M20, Option: 1/2" NPTF |
| Electrode and grounding | Stainless Steel 316L, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum, Tungsten Carbide |
| Grounding electrode | DN10A / 10: use Grounding Ring * 1 pc, DN15-2000: 3 Electrodes |
| Process connection | Flange |
| Flange type | JIS 10K / JIS 20K / JIS 40K, ANSI 150# / ANSI 300# / ANSI 600#, DIN PN10 / PN16 / PN25 / PN40 |
| Grounding resistance | Must be less than 10 Ω |
| Accuracy | ±0.4% of reading (velocity ≥0.5 m/s); ±0.0025 m/s (velocity <0.5 m/s); ±0.2% of reading (with AMC3200 / 3200E converter) |
| Temperature | -20~70°C (Polyurethane, PU), -20~70°C (Neoprene), -40~120°C (PTFE 1"-10", FEP/PFA 3/8"-12"), -40~140°C (PTFE 1"-6", FEP/PFA 3/8"-12"), -40~180 °C (PFA 3/8"-12") |
| Ambient temperature | -25~60°C |
| Maximum pressure | 350 kgf/cm2 |