AMC3200DF Series
ALIA
AMC3200DF Series
Datasheet (PDF) ↗Dual-frequency electromagnetic flow converter
Uses dual-frequency excitation for demanding conductive liquid applications, including slurries. It is designed for measurements affected by process-generated signal noise.
SKU: AN2003
Add to quotation list +Technical specifications
| Excitation | Dual Frequency Excitation |
|---|---|
| Display | 3 Lines LCD with illumination Line 1: 9 Digit totalizer for forward flow, 9 Digit totalizer for reverse flow, 9 Digit totalizer for difference Line 2: 5 Digit flowrate / velocity / % / mA /Hz Line 3: Parameter / Query / Clr tot / Query LOG Alarm, Guidance Totalizer Unit: t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal, Mgal, bbl, ft3, a-ft Time Unit: sec, min, hour, day |
| Measuring range | Min. 0-0.15 m/s Max. 0-15 m/s |
| Accuracy | +/-0.4% of reading (Velocity≥1.0 m/s) +/-0.002 m/s (Velocity: 0.3…1.0 m/s) |
| Repeatability | +/-0.2% value of reading |
| Current output | 4-20 mA (Isolated) Load: Max. 500 Ω |
| Pulse output | Open Collector Rating: 3-30 VDC, 50 mA Max. |
| Pulse frequency | 1) Scaled pulse (mL/Pulse, L/Pulse, Other) 2) Frequency: 0-5000 Hz |
| Pulse width | 50% of band width |
| Alarm | High / Low with open collector output Rating: 3-30 VDC, 50 mA Max. |
| Communication | Bluetooth (Android) Standard RS485 (MODBUS Protocol) Standard HART signal (Compatible) Optional |
| Keypad | 3 Internal keys for programming and display control |
| Data retention | Operation parameter and totalizer figures are stored by EEPROM for more than 10 years |
| Low-flow cut-off | 0-9.9% |
| Damping | 0-99 Seconds |
| Density setting | 0.001-9.999 g/cm3 |
| Self-diagnostics | The following error messages are displayed if failure occurs: -Abnormal sample -Pulse width -Overanged output -Internal error -Overflow -Empty pipe |
| Cable entry | Standard: M20 Option: 1/2" NPTF |
| Ingress protection | IP67, Explosion Proof, Ex d ia [ia] q llC T6 |
| Ambient temperature | -25~65 °C |
| Material | Aluminum alloy |
| Power supply | 90-260 VAC, 50/60 Hz 24 VDC +/-10% (Option) |
| Power consumption | 6-8 W (Dependent on sensor size) |
| Weight | 4.5 kg |
| Mounting | Bracket on 2" Pipe |
| Compatible AMF type | AMF900, AMF601, AMF500 |
| Sensor size | DN10-DN450 |