Skip to main content

AMC3200 Series

Request a quotation

Add this product to your quotation list. We will review the options and pricing for your application.

Email us

Information and support

Contact us for help with product selection and your application.

Call us
Home › Flow › AMC3200 Series
ALIA AMC3200 Serisi

ALIA

AMC3200 Series

Datasheet (PDF) ↗

Electromagnetic flow converter

Provides bidirectional flow measurement, totalisation and diagnostics with ALIA AMF electromagnetic sensors. Communication and enclosure options are selected together with the sensor configuration.

SKU: AN2002

Add to quotation list +
Technical specifications
ExcitationDC Plused
DisplayLine 1: 9 Digit totalizer for forward flow, 9 Digit totalizer for reverse flow, 9 Digit totalizer for difference Line 2: 5 Digit flowrate / velocity / % / mA / Hz Line 3: Parameter / Query / Clr tot / Query LOG Alarm, Guidance Totalizer Unit: t, kg, g, lb, Ston, Lton, m3, L, mL, Igal, gal, Mgal, bbl, ft3, a-ft Time Unit: sec, min, hour, day
Measuring rangeMin. 0-0.15 m/s Max. 0-15 m/s
Accuracy±0.2% of reading (velocity ≥0.5 m/s); ±0.001 m/s (velocity <0.5 m/s)
Repeatability±0.05% of reading
Current output4–20 mA (isolated); load: maximum 600 Ω
Pulse outputOpen collector
Pulse frequency1) Scaled pulse (mL/Pulse, L/Pulse, Other) 2) Frequency: 0-5000 Hz
Pulse width50% of band width
AlarmHigh / Low with open collector output Rating: 3-30 VDC, 50 mA Max.
CommunicationBluetooth (Android) Standard RS485 (MODBUS Protocol) Standard HART signal (Compatible) Optional
Keypad3 Internal keys for programming and display control
Data retentionOperation parameter and totalizer figures are stored by EEPROM for more than 10 years
Low-flow cut-off0-9.9%
Damping0-99 Seconds
Density setting0.1-9.99 g/cm3
Self-diagnosticsThe following error messages are displayed if failure occurs: – Abnormal sample – Pulse width – Overanged output – Internal error – Overflow – Empty pipe
Cable entryStandard: M20 Option: 1/2" NPTF
Ingress protectionIP67, Explosion Proof, Ex d ia [ia] q llC T6
Ambient temperature-25~65 °C
MaterialAluminum alloy
Power supply90-260 VAC, 50/60 Hz 24 VDC +/-10% (Option)
Power consumption3-17 W (Dependent on sensor size)
Weight4.5 kg
MountingBracket on 2" Pipe